MUE 現代超音波有限公司 Modern Ultrasonic Engineering Co., Ltd.

http://www.mue.com.tw

Products  About us  Contact us  News  Technology

Ultrasonic Testing

   

■

 

MUE18T Ultrasonic

Pressure Meter

■

 

MUE19 Ultrasonic

Pressure Monitor

■

 

MUE180GI Ultrasonic

Pressure Test Rods

■

 

MUE180GL Ultrasonic

Pressure Test Rods

■

 

MUE180TI&TL Ultrasonic

Pressure Test Rods

■

 

MUE180SI Ultrasonic

Pressure Test Rods

   

Ultrasonic PROCESSING

   

■

 

MUE102

Ultrasonic Generator

■

 

MUE32H High-frequency

Ultrasonic  Generator

■

 

Ultrasonic Vibration 

Plate  &  Tank

■

 

MUE13C Tabletop  

Ultrasonic Cleaner

■

 

MUE33C  Focused

Ultrasonic Processor

■

 

MUE68 Multi-Purpose 

DC Power Supply

   

MUE32H High frequency Ultrasonic Generator

Overview

 Front panel

 

Rear panel

Front panel

* Frequency Indicator

* Frequency Fine Tune

* Frequency Mode Set

* Frequency Sweep Range Adjust

* Frequency Sweep Level Adjust  

* Power Set

* Power Level Indicator

* Green Power Indicator

* Red Over Heat Protect Indicator

* Power Switch

Rear panel

* Output Socket

* Remote & Alarm Sockets

* Remote & Alarm Output Terminals

* Power Supply Socket

 

instructions

[a]

Plug the cable of the ultrasonic vibration tank or plate to the output socket of the unit. Check the specifications of the vibration tank or plate are correct and match the generator. Also check the water level is correct. 

[b]

Connect the power cord to the AC outlet. Check the supply voltage is correct. Turn on the power.

[c]

Check the output power level is OK. Adjust the Power Set to obtain the appropriate output power. If need, adjust the frequency fine tune to eliminate the temperature effect to maintain the best working condition.

[d]

The electric energy output by ultrasonic generator to drives the oscillators produce ultrasonic energy, which is then transferred to the water inside the vibration tank to play a cleaning function. If the ultrasonic energy cannot be transmitted to the water, it will cause damage to the oscillators. Therefore, the following situations must be avoided.

[1]Power on while no water in the vibration tank.

[2]Vigorously stir the water in the vibration tank. If find that there is no vibration wave in the water because of this, please turn off the power and wait for 3~5 minutes before turning the power back on.

[3]The water contains too much chlorine or other gases. It also hinders the transmission of ultrasonic energy. It is necessary to wait 15~30 minutes for the gas content to drop before turn on the power.

[e]

If the frequency mode is selected the optional-setting,  the sweep range of frequencies and level can be adjusted for the appropriate condition over a wider range than the preset mode.

[f]

After use, turn off the power.

 

Last Update:2022-06-18

 

Language

 

■

 

中文 Chinese

 

■

 

英文 English  

 

Contact us

Tel:886-2-2626-3081

Fax:886-2-2626-3021

E-mail:tl@mue.com.tw

Technology

 

■

 

FAQs

 

 

Back to MUE32H

Copyright © Modern Ultrasonic Engineering Co., Ltd. 現代超音波有限公司