MUE33C Focused
Ultrasonic Processor
Overview
|
Generator Front panel
Generator Rear panel |
Generator
Front panel
* Power Level
Indicator
* Power Set
* Frequency Fine
Tune
*
Green Power Indicator
* Red Over Heat
Protect Indicator
* Power Switch
Generator
Rear panel
* Output socket
* Power socket
* Remote & Alarm
Output Terminals |
Vibrator |
Vibrator
* Ultrasonic
Vibrator
* Soundproof Box
* SUS304
Focused Vibration rod
* Glass Measuring Cup
* Anti-slip Mat
* Stainless steel
lifting frame
|
Instructions |
[1] |
Plug the cable of the
ultrasonic vibrator to
the output socket of the
generator. Check their
specifications are correct and
match.
Also check that the
vibration rod position
in the measuring cup and
avoid touching the
measuring cup. |
[2] |
Connect the power
cord to the AC outlet.
Check the supply
voltage is correct. Turn on the power. |
[3] |
Check the working state
after starting the
machine. Normally, the
Power Set
is adjusted to the
maximum position; the
Frequency Fine Tune is
adjusted to the best
point, so that the
vibration rod is in the
strongest state of
vibration, the Power
Level Indicator should
be fully on.
If needed, adjust the
Power Set
to obtain the
appropriate output
power, also adjust the
Frequency Fine Tune to
maintain the best
working condition.
|
[4] |
Due to the large noise
generated during
vibration, it can be up
to more than 105dB.
Therefore, when using,
close the soundproof box
or wear soundproof
earplugs to reduce the
noise
hazard. |
[5] |
The stainless steel
lifting frame can adjust
the height of the
measuring cup as needed
to control the depth of
the vibration rod into
the liquid of the
measuring cup. The rod
more closer to the
bottom of the measuring
cup, the more obvious
the air explosion
phenomenon, can be
adjusted as needed.
Anti-slip mat must be
added between the
lifting frame and the
measuring cup to prevent
from sliding.
|
[6] |
The stainless steel
lifting frame and base
are not fixed, and there
are anti-slip mat. When
putting in and taking
out the measuring cup,
it is recommended to
hold the measuring cup
by one hand, and to put
in and take out the
lifting frame by another
hand, eliminating the
need to repeatedly
adjust the height each
time, saving time and
convenient operation.
|
[7] |
When need to work for a
long time, during the
period, please pay
attention to whether the
working state of the
vibrator is affected by
the influence of the
ambient temperature,
etc. If necessary,
adjust the frequency
fine tune to maintain
the optimal condition.
Also note that after the
liquid absorbs the
ultrasonic energy, the
temperature will
gradually increase.
|
[8] |
After
use, turn off
the power.
|
Last Update:2022-06-18 |